Water Purifier

Ultrapure Water Purifier SCSJ-10L SCSJ-20L SCSJ-30L

Model Standard SCSJ-10L SCSJ-20L SCSJ-30L Eliminating endotoxin SCSJ-10F SCSJ-20F SCSJ-30F Low TOC SCSJ-10V SCSJ-20V SCSJ-30V Synthesizing SCSJ-10VF SCSJ-20VF SCSJ-30VF

Specially designed for the high-precision laboratory. Low ion, organic matter content, heat source and nucleic acid enzyme. Multi - step purification process, UV sterilization and ultra-filtration technologies.

Power
48~72W
Dimensions
410*270*500mm
A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features:

1. Real – time LCD display. 

2. Alternative water bucket size to meet different needs. 

3. New type filter cartridge, no water seepage and leakage. 

4. Easy to maintenance and replacement for the filter cartridge. 

5. Automatic electronic pressure sensor controlling, RO membrane auto flushing. 

Technical Parameters:

Model

Standard

SCSJ-10L

SCSJ-20L

SCSJ-30L

Eliminating Endotoxin

SCSJ-10F

SCSJ-20F

SCSJ-30F

Low TOC

SCSJ-10V

SCSJ-20V

SCSJ-30V

Synthesizing

SCSJ-10VF

SCSJ-20VF

SCSJ-30VF

Output(25°C)

10 series-10L/H, 20 series-20L/H, 30 series-30L/H

Flow Rate

Up to 2 liters/minute(with pressure tank)

Water Output Type

RO and ultra-pure water

Resistivity(25°C)

18.2MΩ.cm

TOC*

<10ppb <10ppb <3ppb <3ppb

Bacteria

<0.1cfu/ml

Particle(>0.22μm)

<1/ml

Endotoxin

N/A <0.001Eu/ml N/A <0.001Eu/ml

Ion Rejection Rate

95%~99%(new RO membrane)

Particles and Bacteria Rejection Rate

>99%

Water Supply Requirements

Tap water, TDS<200ppm, 5~45°C, 1.0~4.0kgf/cm2

Standard Configuration

Main body(including 1 set of cartridge), 12 liters pressure tank

Purification System

Pretreatment Unit

11″ U type Quick-Insert PP Cotton Filter*1

11″ U Type Quick-Insert Active Carbon Filter*2

RO Unit

75 GPD RO membrane*1(for 10L)

150 GPD RO membrane*1(for 20L)

200 GPD RO membrane*1(for 30L)

Subsequent Unit

11″ U Type Quick-Insert Ultra Purification Column*4

0.2μm PES terminal filter*1

Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series)

Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series)

Consumption

48~72W

Power Supply

AC110/220V±10%, 50/60Hz

External Size(W*D*H)

410*270*500mm

Package Size(W*D*H)

550*630*750mm

Gross Weight

40kg

Remarks: *The value will be influenced by temperature and feed water’s quality.

The details

Specifications

Model
StandardSCSJ-10LSCSJ-20LSCSJ-30L / Eliminating EndotoxinSCSJ-10FSCSJ-20FSCSJ-30F / Low TOCSCSJ-10VSCSJ-20VSCSJ-30V / SynthesizingSCSJ-10VFSCSJ-20VFSCSJ-30VF
Output(25°C)
10 series-10L/H, 20 series-20L/H, 30 series-30L/H
Flow Rate
Up to 2 liters/minute(with pressure tank)
Water Output Type
RO and ultra-pure water
Resistivity(25°C)
18.2MΩ.cm
TOC*
<10ppb / <10ppb / <3ppb / <3ppb
Bacteria
<0.1cfu/ml
Particle(>0.22μm)
<1/ml
Endotoxin
N/A / <0.001Eu/ml / N/A / <0.001Eu/ml
Ion Rejection Rate
95%~99%(new RO membrane)
Particles and Bacteria Rejection Rate
>99%
Water Supply Requirements
Tap water, TDS<200ppm, 5~45°C, 1.0~4.0kgf/cm2
Standard Configuration
Main body(including 1 set of cartridge), 12 liters pressure tank
Purification System
Pretreatment Unit / 11" U type Quick-Insert PP Cotton Filter*111" U Type Quick-Insert Active Carbon Filter*2 / 11" U type Quick-Insert PP Cotton Filter*111" U Type Quick-Insert Active Carbon Filter*2 / 11" U type Quick-Insert PP Cotton Filter*111" U Type Quick-Insert Active Carbon Filter*2
Purification System
RO Unit / 75 GPD RO membrane*1(for 10L)150 GPD RO membrane*1(for 20L)200 GPD RO membrane*1(for 30L) / 75 GPD RO membrane*1(for 10L)150 GPD RO membrane*1(for 20L)200 GPD RO membrane*1(for 30L) / 75 GPD RO membrane*1(for 10L)150 GPD RO membrane*1(for 20L)200 GPD RO membrane*1(for 30L)
Purification System
Subsequent Unit / 11" U Type Quick-Insert Ultra Purification Column*40.2μm PES terminal filter*1Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series)Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series) / 11" U Type Quick-Insert Ultra Purification Column*40.2μm PES terminal filter*1Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series)Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series) / 11" U Type Quick-Insert Ultra Purification Column*40.2μm PES terminal filter*1Imported PES 5000 Dalton UF Heat Source Column*1(for SCSJ-F and SCSJ-VF series)Dual wavelength(185&254nm) UV lamp(import)*1(for SCSJ-V and SCSJ-VF series)
Consumption
48~72W
Power Supply
AC110/220V±10%, 50/60Hz
External Size(W*D*H)
410*270*500mm
Package Size(W*D*H)
550*630*750mm
Gross Weight
40kg
How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team