PH Meter

Benchtop pH/ORP/Ion Meter

Model PH-A120-CNPH-A120-UK / PH-A130-CNPH-A130-UK / PH-A131 Table-top

1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers Automatic electrode diagnosis shows the pH slope and offset

A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features:

pH:

1. 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers

2. Automatic electrode diagnosis shows the pH slope and offset

3. Solution temperature coefficient compensates for the pure water samples and references the pH to 25°C

ORP:

1. 1 point offset calibration allows adjusting the displayed value to a known standard

2. Relative and absolute millivolt modes ensure the reliable ORP measurements

Ion Concentration:

1. 2 to 5 points calibration, including the 8 concentration points can be selected

2. Electrode management is capable of storing and recalling up to 3 electrode slopes

3. Automatic electrode diagnosis shows the calibration points and slopes

4. Selectable ion measurement methods (direct reading, known addition, known subtraction, sample addition, sample subtraction) and concentration units (ppm, mg/L, mol/L or mmol/L)

Water Hardness:

1. 2 to 5 points calibration from low to high concentrations

2. Selectable measurement units (German degree, English degree, French degree, mmol/L and mg/L) are used for professional water hardness measurements

General Features:

1. Automatic temperature compensation ensures accurate readings over the entire range

2. Auto-Read function senses and locks the measurement endpoint

3. Timed Interval Readings sends the measurement data to a PC or printer

4. Limit Alarm automatically alerts when reading exceeds the specified range

5. Calibration due alarm prompts user to calibrate the meter regularly

6. Password protection prevents the unauthorized calibration and settings

7. Expanded memory stores or recalls up to 1000 data sets

8. Reset function automatically resumes all settings back to the factory defaults

Technical Parameters: 

Model

PH-A120-CN

PH-A120-UK

PH-A130-CN

PH-A130-UK

PH-A131

PH

Range -2.000~20.000pH • • —
Resolution 0.001, 0.01, selectable • • —
Accuracy ±0.002pH • • —
Calibration Points 1 to 5 points • • —
pH Buffer Options USA, NIST, DIN, 5 custom buffers • • —

ORP(optional)

mV Range ±2000.0mV • • •
Relative mV Range ±2000.0mV • • —
Resolution 0.1mV • • •
Accuracy ±0.2mV • • •
Calibration Points 1 point • • —

Ion

Range 0.001~30000 (depending on the range of ISE) — • •
Resolution 0.001, 0.01, 0.1, 1 — • •
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent) — • •
Measurement Units ppm, mg/L, mol/L, mmol/L — • •
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) — • •
Measurement Methods Direct reading, known addition, known subtraction, sample addition, sample subtraction — • •
Electrode Management 1 to 3 electrodes — • •

Water Hardness

Range 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) — • •
Resolution 0.001, 0.01, 0.1, 1 — • •
Accuracy ±1% F.S. — • •
Calibration Points 2 to 5 points (0.01, 0.1, 1, 10, 100mmol/L) — • •

Temperature

Range 0~105°C/32~221°F • • •
Resolution 0.1°C/0.1°F • • •
Accuracy ±0.5°C/±0.9°F • • •
Offset Calibration 1 point, reading ±10°C • • •

Other Specifications

Temperature Compensation 0~100°C, manual or automatic • • •
Solution Temperature Coefficient 25°C • • —
Stability Criteria Standard or high-accuracy • • •
Calibration Due Alarm 1 to 31 days or off • • •
Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off • • •
Password Protection 4 digits • • •
Memory 1000 data sets • • •
Communication Interface USB • • •
Connector BNC, 3.5 mm jack socket • • •
Display 7 inches TFT LCD • • •
Power Supply Standard: 220V 50/60Hz; Optional: 110V, 50/60Hz;  DC12V power adapter • • •
Outer Dimensions

240*220*80mm

Net Weight

1.7kg

Packing Size

320*250*200mm

Gross Weight

1.8kg

Remarks:

• means with; — means without.

Difference of PH-A120/130-CN& PH-A120/130-UK:

1. PH-A120/130-CN electrode is E201-BNC plastic body pH electrode, PH-A120/130-UK electrode is P11 glass pH electrode

2. PH-A120/130-UK is more accurate than PH-A120/130-CN

Ordering Information:

1. PH-A120/130-CN: Meter, E201-BNC plastic body pH electrode, temperature probe, pH buffer sachets, electrode holder and power adapter

2. PH-A120/130-UK: Meter, P11 glass pH electrode, temperature probe, pH buffer sachets, electrode holder and power adapter

3. PH-A131: Meter, ion selective electrode, temperature probe, standard solutions (100/1000ppm), ionic strength adjuster, electrode holder and power adapter

The details

Specifications

Ask our team for the full specification sheet for this model.

How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote