Spectrophotometer

Atomic Absorption Spectrophotometer BK-AA4530F

Model BK-AA4530F

The Atomic Absorption Spectrophotometer(AAS) is a highly precise analytical instrument designed for detecting and quantifying metal elements in various samples.

Power
7000W
A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features:

1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer(optional).

2. Integrated floated optical platform design improves the optical system shock resistance stable.

3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

4. Position adjusting: the flame burner can be set on the best position automatically.

5. Fully automated wavelength scanning and peak searching.

6. Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

7. Deuterium lamp and self-absorption background calibration.

8. Measuring method: flame absorption method and emission method.

9. Result printing: parameter, data result and diagram.

10. Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

Technical Parameters:

Model BK-AA4530F
Wavelength Range 190~900nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy ≤±0.15nm
Wavelength Repeatability ≤0.04nm
Base Line Stability ≤0.002A/30min(Cu)
Characteristic Concentration 0.02μg/ml/1%(Cu)
Detection Limit 0.004μg/ml(Cu)
Preciseness 0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Calibration When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Power Supply 220V, 50Hz
Packing Size(W*D*H) 860*705*755mm(Main instrument); 1170*650*900mm(Accessories)
Gross Weight 100.8kg(Main instrument); 65kg(Accessories)
Standard Accessories Software; Inkjet printer; Oil free air compressor;

Acetylene reducing valve; Cu hollow cathode lamp; Air filter

Optional Accessories Graphite furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler

Flame System:

Acetylene Air Burner 100mm
Ignition Dynamic Baseline Drift ≤0.006A/30min
Characteristic Concentration ≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy ≤0.5%(Cu, absorbance>0.8A) (Detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner

Graphite Furnace(Optional):

Max. Temperature 3000°C
Max Heating Speed ≥2000°C/S
Characteristic Quantity Cd≤0.5*10-12g

Cu≤0.5*10-11g

Accuracy Cu≤3%

Cd≤3%

Safety System Over current protection, Low air pressure alarm/protection, Low cooling water flow alarm/protection
Power Supply 220V, 50Hz
Consumption 7000W
Packing Size(W*D*H) 730*625*700mm
Gross Weight 79.3kg
The details

Specifications

Model
BK-AA4530F
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy
≤±0.15nm
Wavelength Repeatability
≤0.04nm
Base Line Stability
≤0.002A/30min(Cu)
Characteristic Concentration
0.02μg/ml/1%(Cu)
Detection Limit
0.004μg/ml(Cu)
Preciseness
0.5%
Grating
1800 lines/mm
Inflamer
All-metal titanium burner
Atomizer
Effective glass atomizer
Lamp Stand
8
D2 Background Calibration
When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Power Supply
220V, 50Hz
Packing Size(W*D*H)
860*705*755mm(Main instrument); 1170*650*900mm(Accessories)
Gross Weight
100.8kg(Main instrument); 65kg(Accessories)
Standard Accessories
Software; Inkjet printer; Oil free air compressor;Acetylene reducing valve; Cu hollow cathode lamp; Air filter
Optional Accessories
Graphite furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler
Acetylene Air Burner
100mm
Ignition Dynamic Baseline Drift
≤0.006A/30min
Characteristic Concentration
≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy
≤0.5%(Cu, absorbance>0.8A) (Detection limit Cu≤0.008μg/ml)
Safety System
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner
Max. Temperature
3000°C
Max Heating Speed
≥2000°C/S
Characteristic Quantity
Cd≤0.5*10-12gCu≤0.5*10-11g
Accuracy
Cu≤3≤3%
Safety System
Over current protection, Low air pressure alarm/protection, Low cooling water flow alarm/protection
Power Supply
220V, 50Hz
Consumption
7000W
Packing Size(W*D*H)
730*625*700mm
Gross Weight
79.3kg
How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote