PH Meter

Benchtop Multiparameter Water Quality Meter

Model PH-900 Table-top

The Benchtop Multiparameter Water Quality Meter is a high-precision analytical instrument designed for comprehensive water quality analysis in laboratories, research facilities, and industrial applications.

A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features:

pH:

1. Multiparameter water quality meter is equipped with a 6.5 inches backlit LCD display 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.

2. Automatic electrode diagnosis shows the pH slope and offset.

ORP:

1. 1 point offset calibration allows adjusting the displayed value to a known standard.

2. Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration:

1. 2 to 5 points calibration, including the 8 concentration points can be selected.

2. Direct ion concentration readout simplifies the measurement process.

3. Automatic electrode diagnosis shows the calibration points and slopes.

4. Selectable concentration units(ppm, mg/L, mol/L, mmol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity:

1. 1 to 5 points calibration with automatic recognition for conductivity standards.

2. Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.

3. Automatic electrode diagnosis shows the calibration points and factors.

Dissolved Oxygen:

1. 1 or 2 points calibration using the air-saturated water or zero oxygen solution.

2. Salinity and barometric pressure compensations eliminate the measurement error.

Other Features:

1. Automatic temperature compensation ensures accurate readings over the entire range.

2. Auto-Read function senses and locks the measurement endpoint.

3. Calibration due alarm prompts user to calibrate the meter regularly.

4. Setup menu allows setting the number of calibration points, resolution, stability criteria,temperature unit, date and time, etc.

5. Reset function automatically resumes all settings back to the factory defaults.

6. Expanded memory stores or recalls up to 500 data sets.

7. USB communication interface for data transfer and timed interval readings.

Accessories:

pH/conductivity/dissolved oxygen electrodes, temperature probe, pH buffer sachets, conductivity standard solutions, DO electrolyte solution, membrane cap, electrode holder, USB cable and power adapter

Technical Parameters:

Model

PH-900

pH

Range -2.000~20.000pH
Resolution 0.001, 0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers

ORP(Optional)

Range ±1999.9mV
Resolution 0.1,1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point

lon(Optional)

Range 0.001-19999(depending on the range of ISE)
Resolution 0.001, 0.01,0.1, 1
Accuracy ±0.5%F.S.(monovalent), ±1%F.S.(divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points(0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)

Conductivity

Range 0.1~2μS/cm(CON-0.1.optional); 2~20mS/cm(CON-1, standard); 20~200mS/cm(CON-10, optional)
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5%F.S.
Calibration Points 1 to 5 points
Calibration Solutions 10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear(0.0~10.0%/°C), pure water
Reference Temperature 20/25℃
Cell Constant K=0.1, 1, 10 or custom

TDS

Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01, 0.1, 1
Accuracy ±1%F.S.
TDS Factor 0.1~1.0(default 0.5)

Salinity

Range 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01
Accuracy ±1%F.S.

Resistivity

Range 0.00~20.00MΩ
Resolution 0.01
Accuracy ±1%F.S.

DO

Range 0.00~20.00mg/L, 0.0~200.0% saturation
Resolution 0.01mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0%
Calibration Points 1 or 2 points
Barometric Pressure Correction 60.0~112.5kPa/450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual

Other

Specifications

Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements DC5V power adapter
Dimension 210*188*60mm
Net Weight 1.5kg
Packing Size 300*250*200mm
Gross Weight 1.7kg
The details

Specifications

Ask our team for the full specification sheet for this model.

How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote