Gas Chromatograph BK-GC112A
Model BK-GC112AThe Gas Chromatograph(GC) is a high-precision analytical instrument used for the separation, identification, and quantification of volatile and semi-volatile compounds in complex mixtures.
Featuring a more expandable three-chamber design, it can accommodate five valves, seven columns, and dual-column chambers with independent temperature control. The fully upgraded electronic flow and pressure control system (EPC) boasts a pressure control accuracy of up to 0.001 psi, and the new temperature control system achieves a temperature control accuracy of 0.01℃. Based on industry-leading design concepts and an independently developed data processing system, this instrument not only achieves a significant improvement in performance but also demonstrates exceptional strength in expandability and flexibility.
Ask about availability, configuration and delivery to your location. We reply personally.
Enquiry only. No payment is taken.Features:
1. Supports up to 18 channels of high-precision electronic pressure/flow control (EPC).
2. Featuring a 7-inch high-definition capacitive touchscreen, it can display spectra, all temperature zones, carrier gas flow rates, detector functions, etc. in real time.
3. Instrument methods can be edited on-screen, and firmware versions can be upgraded via USB interface.
4. One-click instrument reset is supported.
5. Intelligent maintenance tracking and reminders are provided, indicating the replacement time for injection pads, liners, etc.
6. The pre- and post-chromatographic channels can be controlled and operated synchronously or asynchronously.
7. It has undergone rigorous functional safety ECM certification, comprehensively enhancing its anti-interference capabilities.
Technical Parameters:
| Model |
BK-GC908 |
|
|
Oven |
Temperature Range | RT+2~450℃ |
| Temperature Control Accuracy | 0.01℃ | |
| Temperature Program | ≥99 levels, 100 platform (expandable) | |
| Maximum Temperature Heating Rate | 250ºC/min | |
| Temperature Control System | An 8-channel independent temperature control system with automatic temperature protection function | |
|
Selectable Detector Types |
Flame Ionization Detector (FID) |
Operating temperature: 450℃ |
| Detection limit ≤ 1.1 pg C/s (n-hexadecane) | ||
| Baseline drift (30 min) ≤ 2*10⁻¹³ A | ||
| Baseline noise ≤2*10⁻14A | ||
| Dynamic linear range ≥10⁷ | ||
| Automatic ignition function | ||
|
Thermal Conductivity Detector (TCD) |
Sensitivity≥10,000 mV·mL/mg | |
| Baseline drift (30 min): ≤0.2 mV | ||
| Baseline noise: ≤0.05mV | ||
| Dynamic linear range: ≥10⁵ | ||
| Safety protection: Gas bridging current protection function | ||
|
Flame Photometric Detector (FPD) |
Maximum operating temperature: 450℃ | |
| Limits of detection: P ≤ 80 fg/s (methyl parathion), S ≤ 8 pg/s (methyl parathion) | ||
| Dynamic linear range: P≥10³; S≥10² | ||
| Equipped with automatic ignition function | ||
|
Electron Capture Detector (ECD) |
Radioactive source: 63Ni | |
| Maximum operating temperature: 400℃ | ||
| Limit of detection: ≤1.0*10-14 g/mL (γ-666) | ||
| Dynamic linear range: ≥10⁴ | ||
|
Nitrogen-phosphorus Detector (NPD) |
Maximum operating temperature: 400℃ | |
| Limit of detection: N: ≤1*10⁻¹² g(N)/s (azobenzene); P: ≤5*10⁻¹³ g(P)/s (malathion) | ||
| Dynamic linear range: N≥10³, P≥10³ | ||
| Selectable Sample Injection Method |
It can be used with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc. |
|
| Standard Accessories |
FID detector, general chromatography workstation software, capillary sampler, startup toolkit |
|
| Optional Accessories |
Sample injection system, TCD, ECD, FPD and NPD detector, audit chromatography workstation software, chromatographic column, nickel catalytic converter, liquid autosampler, headspace sampler |
|
| Power Supply |
AC220V, 50/60Hz |
|
| Product Size(W*D*H) |
670*580*500mm |
|
| Net Weight |
60kg |
|
| Packing Size(W*D*H) |
840*720*750mm |
|
| Gross Weight |
73kg |
|
Remark: 3 different types of detectors can be installed simultaneously.
Ask our team for the full specification sheet for this model.
Request a quote on WhatsApp, or add several items to your enquiry list and send them together.
We confirm configuration, voltage, accessories, availability and a delivered price.
We handle procurement, packing and international shipping to your facility.