New Products

Freezing Point Osmometer BK-FPO-V2

Model BK-FPO-V2

Introduction The freezing point osmometer produced by our company with independent research and development is in accordance with Raoul freezing point theory, based on the solution freezing point declined value proportional to the solution molar concentration, using high sensitivity of temperature-sensing element, to measure the freezing point of different solutions, so as to derive the osmotic pressure molar concentration. This theory has been widely used for the test and research of osmotic pressure molar concentration in the fields such as pharmaceuticals, pharmaceutical analysis, biological and food therapy

Net weight
12kg
Dimensions
225*275*345mm
A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Feature:

1.It has the functions of electronic signature and user classification management, to satisfy CFR PART21 store data query according to time which can store 3 years of testing data.

2.It can carry on sing le-point or multi-point linear calibration, to ensure that the instrument has the detection accuracy of each range interval in stability.

3.Temperature probe adopts the screw linear guide motor design, So that the operation just on a touch screen can complete the whole test process.

4.It adopts double refrigeration system, with a short pre-cooling time, fast detection speed, to facilitate continuous detection.

5.It can simultaneously display the osmotic pressure molar concentration value, the freezing point value and the molar concentration ratio.

6.The cooling system adopts the athermal transfer fluid design, to exempt from frequent maintenance.

7.Built-in “Chinese pharmacopoeia” hundreds of injectable drug name can facilitate the preset information of test sample.

Technical Parameter:

Model BK-FPO-V2
Measurement Range 0~2000 mOsmol
Sample Amount 100μl
Testing Duration ≤3min
Pre-Cooling Time ≤3min
Measurement Error ≤1%
Repeatability ≤1%
Linearity ≤1%
Print Built-in printer
Audit Trail Optional
Environment Temperature 0~30℃ Recommended for 15~25℃
Relatively Humidity ≤60%
Power Supply 220V,50/60Hz (Standard); 110V, 60Hz (Optional)
External Size(W*D*H) 225*275*345mm
Packed Size(W*D*H) 420*545*580m
Net weight 12kg
Gross weight 25kg
The details

Specifications

Model
BK-FPO-V2
Measurement Range
0~2000 mOsmol
Sample Amount
100μl
Testing Duration
≤3min
Pre-Cooling Time
≤3min
Measurement Error
≤1%
Repeatability
≤1%
Linearity
≤1%
Print
Built-in printer
Audit Trail
Optional
Environment Temperature
0~30℃ Recommended for 15~25℃
Relatively Humidity
≤60%
Power Supply
220V,50/60Hz (Standard); 110V, 60Hz (Optional)
External Size(W*D*H)
225*275*345mm
Packed Size(W*D*H)
420*545*580m
Net weight
12kg
Gross weight
25kg
How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote