Other Lab Equipment

Tower UPS

Model BK-U1101B / BK-U1101H / BK-U1102B / BK-U1102H +2

Application: PC, ATM machine, server, network, radio and television, microcomputer room, bank securities network, signal station, mobile base station.

A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Feature:

● Advanced work mode DSP digital control Technology, high performance.

● Protection of comprehensive and reliable it can effectively solve 9 power problems such as power failure, surge, transient, spike, etc.

● The design of optimizing battery pack 1KVA-24VDC/36VDC(optional), 2KVA-48VDC/72VDC(optional) and 3KVA-72/96VDC(optional).

● Function of the charger extension charging current is 1-4A, support extended to 6A.

● Strong adaptability to environment overload capacity is 120%.

● Intelligent management RS232/USB are optional.

● Overload capacity: 105%-125%, 1mins; load>125%,30s turn to bypass output; load>150%,300ms turn off.

Technical Parameter:

Model

BK-U1101B BK-U1101H BK-U1102B BK-U1102H BK-U1103B BK-U1103H

Capacity

1000 VA / 800 W

2000 VA / 1600 W

3000 VA / 2400 W

Input

Voltage

110 – 300 VAC (Auto sensing)

Power

Factor

0.99(nominal output @ full load)

Frequency

46Hz ~55 Hz or 56Hz ~ 64 Hz

Phase

Single phase with ground

Output

Voltage

200/208/220/230/240 VAC

AC Voltage Regulation (Static)

± 1%

Frequency Range

48~ 52 Hz or 58 ~ 62 Hz (Synchronized Range)

50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz (Batt. Mode)

Current Crest Ratio

3:1

Harmonic Distortion

2 % THD (Linear Load),≦ 6 % THD (Non-linear Load)

Waveform (Batt. Mode)

Pure sinewave

Output Factor

0.8 / 0.9

Transfer Time

AC Mode to Batt. Mode:0 ms;

AC Mode to Bypass:4 ms (Typical)

Efficiency (Peak)

AC Mode (@100% RCD load):88%

Battery Mode (@100% RCD load):83%

Battery

Type

12V / 9Ah

Battery Numbers 2 External 4 External 6 External
Typical Recharge Time

5 hours recover to 90% capacity

Charging Current

1A

Charging Voltage

27.4 VDC ± 1%

54.8 VDC ±1%

82.2 VDC ±1%

Indicators

LED / LCD Panel: UPS status, Load level, Battery level, and Fault conditions

Environment

Working humidity: 20-95 % RH @ 0- 40°C (non-condensing);

Noise Level: Less than 50dBA @ 1 Meter

Alarm

Battery Mode:Sounding every 4 seconds

Low Battery:Sounding every second

Overload:Sounding twice every second

Fault:Continously sounding

Optional SNMP

Communication:RS232 Card / Optional USB Card, SNMP Card, or AS400 Card available;Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7, Linux, Unix, and MAC.

Optional SNMP:Power management from SNMP manager and web browser.

External Size(W*D*H) mm

145*350*228 145*350*228 190*395*328 190*395*328 190*395*328 190*395*328

Package Size(W*D*H) mm

236*428*333 236*428*333 325*493*458 325*493*458 325*493*458 325*493*458

Net weight (kg)

9.6 4.9 17.5 8.3 23 8.9

Gross weight (kg)

10.7 6.2 19.1 9.6 25 10.3

* If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

* When the temperature is lower than 30°C, the power factor can be adjusted to 0.9.

The details

Specifications

Ask our team for the full specification sheet for this model.

How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote