High Performance Liquid Chromatography

High Performance Liquid Chromatography System BK-1800HPLC

Model BK-1800HPLC

Liquid chromatography is a technique that uses a liquid as the mobile phase to separate mixtures through a stationary phase. It utilizes the differences in partition coefficients and adsorption capacities of various components between the two phases, achieves separation through repeated distribution equilibrium, and combines with detectors for qualitative and quantitative analysis.

Noise
≤0.25*10⁻⁵AU /±1*10⁻⁵…
A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features:

1. The system offers a comprehensive and flexible isocratic mode, and also provides binary gradient and quaternary gradient systems. Detection capabilities include PDA, UV/VIS, FL, RI and ELS.

2. The new optional, solvent manager units can easily switch 4 to 8 kinds of solvent base on binary gradient system. There are several configurations available for user selection.

3. The real-time solvent pressure compensation control enhances detection precision. The integrated check valve ensures stable fluid delivery and simplifies maintenance.

EX1800 HPC High-Pressure Constant Flow Pump:

Liquid Infusion System Type I Reciprocating infusion pumps
Flow Rate Range 62MPa 0.001-10ml/min, 0.001ml/min increment
Max Output Pressure 62MPa(corresponding 9000psi)
Flow Precision ≤0.06%RSD
Flow Accuracy ≤±0.3%
Compression Compensation Automatic, continuous, selectable solvent type
Post-column Cleaning Automatic post-column cleaning function, which can control the cleaning flow rate
Extended Application Record the number of times the plunger rod seal is used

EX1800 BPC Binary High-Pressure Constant Flow Pump:

Liquid Infusion System Type I Reciprocating infusion pumps
Flow Rate Range 62MPa 0.001-10 ml/min, 0.001ml/min increment
Max Output Pressure 62MPa(corresponding 9000psi)
Flow Precision ≤0.06%RSD
Flow Accuracy ≤±0.3%
Compression Compensation Automatic, continuous, selectable solvent type
Post-column Cleaning Automatic post-column cleaning function, which can control the cleaning flow rate
Gradient Setting Range 0~100%
Extended Application Record the number of times the plunger rod seal is used

EX1800 QLPC Quaternary Low-Pressure Constant Flow Pump:

Liquid Infusion System Linear motor digital-driven pump
Flow Rate Range 0.001-10.0ml/min in steps of 0.001
Max Output Pressure 70MPa (corresponding 10150psi)
Flow Precision ≤0.06%RSD
Flow Accuracy ≤±0.3%
Compression Compensation Automatic, continuous, selectable solvent type
Post-column Cleaning Automatic post-column cleaning function, which can control the cleaning flow rate
Gradient Setting Range 0~100%
Online Degassing Degassing channel systec AF
Degassing Chamber 480μl
Extended Application Record the number of times the plunger rod seal is used

EX1800 UV Detector:

Flow Cell Volume Volume 10.0μl; adopts cone structure /With optional temperature control module
Light Source Deuterium lamp
Wavelength Range 190~700nm
Spectrum Bandwidth 8nm
Wavelength Accuracy ±1nm
Wavelength Precision Below 0.1nm
Noise ≤0.25*10⁻⁵AU (static)/±1*10⁻⁵AU (dynamic, under specified test conditions)
Drift ≤0.4*10-4AU/h (static)/±2*10-4AU/h (dynamic, under specified test conditions)
Sampling Frequency Up to 100Hz

EX1800 PDA detector:

Number of Diode Arrays 512
Light Source Deuterium lamp + tungsten lamp
Wavelength Range 190~820nm
Wavelength Precision ±0.5nm
Wavelength Accuracy ±1nm
Noise ±5*10 -6AU, under specified conditions
Drift 1*10-4AU/h, under specified conditions
Sampling Frequency Up to 100Hz
Spectral Bandwidth 10nm
Flow Cell Path Length 5mm(10mm is optional)
Up to 8 channels of digital signal output

Technical Parameters:

Model BK-1800HPLC(Type I)
Isocratic manual system
BK-1800HPLC
(Type II)
Binary gradient manual system
BK-1800HPLC(Type III)
Binary gradient manual system with PDA
BK-1800HPLC
(Type IV)
Quaternary gradient manual system
BK-1800HPLC
(Type V)

Quaternary gradient manual system with PDA

Diode Array Detector / / Yes / Yes
Pump EX1800 HPC*1 EX1800 BPC*1 EX1800 BPC*1 EX1800 QLPC*1 EX1800 QLPC*1
Solvent Tray EX1800 TR*1 EX1800 TR*1 EX1800 TR*1 EX1800 TR*1 EX1800 TR*1
UV Detector EX1800 UV*1 EX1800 UV*1 / EX1800 UV*1 /
Manual Sampler 7725i Yes Yes Yes Yes Yes
C18 5μm ID4.6*250mm Yes Yes Yes Yes Yes
Workstation EX-Clarity C50 Yes Yes / Yes /
Power Supply

AC220/110V, 50/60Hz

Optional Accessory

UV detector, RI detector, PDA detector, ELS detector, FL detector, column,

column oven:

EX1800 CO: Standard column oven; EX1800 CO II: Refrigerated column oven

auto-sampler:

EX1800 AS: Pressure resistant 69MPa, max 108pcs 2mL vials, quadruple protection device

EX1800 AS II: Pressure resistant 69MPa, max 192pcs 2mL vials, quadruple protection device

EX1800 AS C: Pressure resistant 69MPa, max 108pcs 2mL vials, with cooling function

EX1800 AS CII: Pressure resistant 69MPa, max 192pcs 2mL vials, with cooling function

Package Size (W*D*H) 720*580*410mm*3 720*580*410mm*3 720*580*410mm*3 720*580*410mm*3 720*580*410mm*3
Gross Weight 22kg;

20kg;

14kg

31kg;

20kg;

14kg

31kg;

23kg;

14kg

23kg;

20kg;

14kg

23kg;

23kg;

14kg

The details

Specifications

Liquid Infusion System
Type I Reciprocating infusion pumps
Flow Rate Range
62MPa 0.001-10ml/min, 0.001ml/min increment
Max Output Pressure
62MPa(corresponding 9000psi)
Flow Precision
≤0.06%RSD
Flow Accuracy
≤±0.3%
Compression Compensation
Automatic, continuous, selectable solvent type
Post-column Cleaning
Automatic post-column cleaning function, which can control the cleaning flow rate
Extended Application
Record the number of times the plunger rod seal is used
Liquid Infusion System
Type I Reciprocating infusion pumps
Flow Rate Range
62MPa 0.001-10 ml/min, 0.001ml/min increment
Max Output Pressure
62MPa(corresponding 9000psi)
Flow Precision
≤0.06%RSD
Flow Accuracy
≤±0.3%
Compression Compensation
Automatic, continuous, selectable solvent type
Post-column Cleaning
Automatic post-column cleaning function, which can control the cleaning flow rate
Gradient Setting Range
0~100%
Extended Application
Record the number of times the plunger rod seal is used
Liquid Infusion System
Linear motor digital-driven pump
Flow Rate Range
0.001-10.0ml/min in steps of 0.001
Max Output Pressure
70MPa (corresponding 10150psi)
Flow Precision
≤0.06%RSD
Flow Accuracy
≤±0.3%
Compression Compensation
Automatic, continuous, selectable solvent type
Post-column Cleaning
Automatic post-column cleaning function, which can control the cleaning flow rate
Gradient Setting Range
0~100%
Online Degassing
Degassing channel systec AF
Degassing Chamber
480μl
Extended Application
Record the number of times the plunger rod seal is used
Flow Cell Volume
Volume 10.0μl; adopts cone structure /With optional temperature control module
Light Source
Deuterium lamp
Wavelength Range
190~700nm
Spectrum Bandwidth
8nm
Wavelength Accuracy
±1nm
Wavelength Precision
Below 0.1nm
Noise
≤0.25*10⁻⁵AU (static)/±1*10⁻⁵AU (dynamic, under specified test conditions)
Drift
≤0.4*10-4AU/h (static)/±2*10-4AU/h (dynamic, under specified test conditions)
Sampling Frequency
Up to 100Hz
Number of Diode Arrays
512
Light Source
Deuterium lamp + tungsten lamp
Wavelength Range
190~820nm
How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team