Clinical Analytical Instruments

Automated Glycohemoglobin Analyzer AH-600Pro

Model AH-600Pro Table-top

The Automated Glycohemoglobin Analyzer AH-600Pro is a high-throughput benchtop system for quantitative HbA1c measurement in clinical laboratories. It uses ion-exchange HPLC with three elution buffers to deliver precise results in both NGSP and IFCC units within 1 minute per test. The system supports carousel sampler loading and puncture aspiration, features automatic sampling, hemolyzing, and mixing, and includes RFID reagent management and LIS bi-directional transmission for streamlined workflow.

Net weight
20kg
A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features

1. Fast

First test takes 2 minutes

1 Min/Test (60 tests/Hour)

Carousel sampler loading or puncture aspiration

2. Precise

Ion exchange chromatography/Three elution buffers

Report in both NGSP and IFCC results

Sample No.: 033 Sample ID: AI01-02 Position: sample type: hemolyzed blood Name: Gender: Age: Test Time: 2020-08-03 09:42:23
Items Results Unit
HbA1c 10.78 %
HbA1c 94.34 mmol/mol
HbF 1.10 %
HbA1 12.28 %
Name % Time Area
FP 0.09 0.17 0.87
A1A 0.66 0.23 6.34
A1B 0.8 0.29 8.05
F 1.10 0.37 10.57
LA1C+ 1.57 0.48 15.02
SA1C 10.78 0.59 87.82
A0 86.65 0.79 892.90

3. Stable


Correlativity

AH-600Pro Measured Value

Top Brand Analyzer

Measured Value(%)

Repeatability

Intra-batch assays (n=10)

Low High
Mean 5.1% 10.1%
SD 0.05 0.05
CV 0.94% 0.51%

Inter-batch assays (n=20)

Low High
Mean 5.1% 10.2%
SD 0.04 0.06
CV 0.87% 0.56%

4. Easy

One key operation, smart settings

Automatically sampling, hemolyzing and mixing

Applying in whole blood and diluted blood

RFID scanner, management for reagent lot No., expiry date, and residue check

LIS bi-directional transmission with reports in both diagram and text

Hemoglobin A1c

Diagnostic Criteria of Type 2 Diabetes

Standards of Diagnosis Plasma Glucose & HbA1c
Classic symptoms of high blood sugar+ HbA1c ≥6.5 %
or + FPG (Fasting Plasma Glucose) ≥126 mg/dl
or + OGTT (Oral Glucose Tolerance Test) ≥200 mg/dl

If without classic symptoms, each test usually needs to be repeated on a second day to diagnose diabetes.

Testing should be carried out in a health care setting (such as clinics or hospital lab)

Clinical Usage of HbA1c

1. Early screening and diagnosis of diabetes

2. Effect evaluation of glycemic control for treatment adjustment

3. Differential diagnosis between stress hyperglycemia and diabetes

4. Prevention, monitoring and evaluation for complications of diabetes

Regular HbA1c Measurement:

1. Once per 6 months for the diabetics with glycemia well controlled;

2. Once per 3 months for the diabetics with failed glycemia controlled or treatment adjustment needed.

Parameters:

Model AH-600Pro
Measurement Principle Ion-exchange HPLC
Test Mode Standard mode/Variant mode
Throughput Standard mode: 60s/test

Variant mode: 96s/test

Items Standard mode: FP, A1A, A1B, F, LA1C+, SA1C, A0

Variant mode: With additional HbS, HbC, HbD, HbE

Measurement range HbA1c: 3%~20%
Repeatability CV≤1.0%
Sample Type Whole blood and diluted blood
Sample Volume Whole blood: 3μL, diluted blood: 4μL
Sample Management LIS loading, barcode scanning
Sample Position 20 samples (2 carousel sampler, each carousel sampler can load 20 samples)
Sampling Method Carousel sampler loading, puncture aspiration
Result Report Form Graphic report: both chromatogram and test result
HbA1c Report Form In both graphic and value repot with IFCC(mmol/mol) and NGSP(%) results
Consumable Elution buffer, hemolysis & wash solution, column, filter, calibrator, control
Reagent Management RFID scanning, automatically loading info of lot, expiry date and remains, etc.
Operation Interface 8 inches touch screen
Storage Capacity 100,000 results. Available for statistics, online queries, data backup, data export
Export &Communication Bi-directional LIS, USB port, Ethernet interface, Built-in thermal printer
Maintenance Automatic maintenance in startup and off, alarm and error indication, daily maintenance reminder & guidance
Power Supply AC100~240V, 50/60Hz
Product Size(W*D*H) 306*466*435mm
Net Weight 20kg
Packing Size(W*D*H) 560*460*700mm
Gross Weight 28kg

Reagent

Reagent Qty Specification
Eluent 1 1 Bottle 800ml/Bottle, room temperature
Eluent 2 1 Bottle 800ml/Bottle, room temperature
Eluent 3/4 1 Bottle 800ml/Bottle, room temperature
Hemolysis &Wash Solution 1 Bottle 2000ml/Bottle, room temperature
Chromatography Column 1 Piece 1 Column/Kit, 4~15℃
Filter 1 Piece 600 Tests/Change, room temperature
Calibrator 1 Kit 1 Vial*Level 1+1 Vial*Level 2

4mL/vial, 2~8℃

Quality Control 1 Kit 1 Vial*Level 1+1 Vial * Level 2

0.5mL/vial, 2~8℃

The details

Specifications

Model
AH-600Pro
Measurement Principle
Ion-exchange HPLC
Test Mode
Standard mode/Variant mode
Throughput
Standard mode: 60s/testVariant mode: 96s/test
Items
Standard mode: FP, A1A, A1B, F, LA1C+, SA1C, A0Variant mode: With additional HbS, HbC, HbD, HbE
Measurement range
HbA1c: 3%~20%
Repeatability
CV≤1.0%
Sample Type
Whole blood and diluted blood
Sample Volume
Whole blood: 3μL, diluted blood: 4μL
Sample Management
LIS loading, barcode scanning
Sample Position
20 samples (2 carousel sampler, each carousel sampler can load 20 samples)
Sampling Method
Carousel sampler loading, puncture aspiration
Result Report Form
Graphic report: both chromatogram and test result
HbA1c Report Form
In both graphic and value repot with IFCC(mmol/mol) and NGSP(%) results
Consumable
Elution buffer, hemolysis & wash solution, column, filter, calibrator, control
Reagent Management
RFID scanning, automatically loading info of lot, expiry date and remains, etc.
Operation Interface
8 inches touch screen
Storage Capacity
100,000 results. Available for statistics, online queries, data backup, data export
Export &Communication
Bi-directional LIS, USB port, Ethernet interface, Built-in thermal printer
Maintenance
Automatic maintenance in startup and off, alarm and error indication, daily maintenance reminder & guidance
Power Supply
AC100~240V, 50/60Hz
Product Size(W*D*H)
306*466*435mm
Net Weight
20kg
Packing Size(W*D*H)
560*460*700mm
Gross Weight
28kg
How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote