Other Lab Equipment

Automatic Thermal Desorption Instrument

Model BK-TD50A

BK-TD50A automatic thermal desorption device can be loaded into 50 position sample tube at a time with full load, and can be used with all domestic and imported GC and GCMS.

Net weight
39kg
Dimensions
432*508*600mm
A tailored quote, without the guesswork.

Ask about availability, configuration and delivery to your location. We reply personally.

Request a quote
Enquiry only. No payment is taken.
  • Specifications confirmed with you before any order
  • International delivery arranged to your facility
  • Personal sourcing support from first message to arrival
A closer look

About this equipment

Features:

1. Power on self-test, fault alarm and prompt function, temperature overload protection function, leakage protection function, gas path differential pressure alarm function, etc., which improves the safety factor of the instrument.

2. The sample position is up to 50, which can meet the daily sample analysis.

3. The adsorption tube can automatically take off the cap and put on the cap automatically, and automatically detect the gas path leakage.

4. Electronic pressure and flow display function.

5. The imported switching valve and solenoid valve are used for gas path control, which has stable performance and effectively prevents sample contamination.

6. All gas pipes have been passivated.

7. New human-computer interaction interface, separate function of detection method, real-time cloud chart display working state, running time, flow, etc.

8. The program control of sample coil position can realize the specified pipe position detection, and can add sample tube at any time according to the demand, which makes the detection process more flexible and smooth.

9. The GC and workstation can be started synchronously, and the anticontrol between GC and GC can also be realized.

10. The machine has the function of analog sampling of standard sample, which is convenient to obtain the working curve.

11. Low temperature secondary desorption function, using electronic refrigeration and two-stage flash thermal desorption process.

12. It has the function of sample diversion, which can prevent contamination of the instrument when detecting high concentration samples.

13. Add log, help, stopwatch and other functions to provide more convenience.

Application:

Meet the following standards:

1. HJ/644-2013 determination of volatile organic compounds in ambient air by adsorption tube sampling thermal desorption gas chromatography mass spectrometry.

2. HJ/t400-2007 sampling and determination method of volatile organic compounds and aldehydes and ketones in vehicles.

3. GB/t18883-2002 indoor air quality standard.

4. HJ/583-2010 determination of Benzene Series in ambient air by solid adsorption / thermal desorption gas chromatography.

5. Hj734-2014 determination of waste volatile organic compounds from stationary pollution sources by solid phase adsorption / thermal desorption gas chromatography.

6. GB / 50325-2020 standard for indoor environmental pollution control of civil building engineering, etc.

Technical Parameters:

Model BK-TD50A
Primary Desorption Temperature RT~400℃, incremental 1°C any set
Injection System Temperature RT~300℃, incremental 1°C any set
Sample Transfer Tube Temperature RT~300℃, incremental 1°C any set
Secondary Desorption Temperature RT~400℃, incremental 1°C any set;

Heating rate>2000℃/min

Cold Trap Temperature -35~50°C, incremental 1°C any set(using electronic refrigeration device, no need for liquid nitrogen refrigeration)
Temperature Control Accuracy ±1℃
Temperature Control Gradient ±1℃
Sample Position 50 positions
Desorption Recovery Rate >98%(related to components)
Backflushing Cleaning Flow 0~100ml/min(continuously adjustable)
Analog Sampling Flow 100ml/min
Power Supply AC220V, 50/60Hz (Standard); 110V, 60Hz(Optional,External transformer)
External Size(W*D*H) 432*508*600mm
Net Weight 39kg
Package Size(W*D*H) 760*610*800mm
Gross Weight 55kg
The details

Specifications

Model
BK-TD50A
Primary Desorption Temperature
RT~400℃, incremental 1°C any set
Injection System Temperature
RT~300℃, incremental 1°C any set
Sample Transfer Tube Temperature
RT~300℃, incremental 1°C any set
Secondary Desorption Temperature
RT~400℃, incremental 1°C any set; Heating rate>2000℃/min
Cold Trap Temperature
-35~50°C, incremental 1°C any set(using electronic refrigeration device, no need for liquid nitrogen refrigeration)
Temperature Control Accuracy
±1℃
Temperature Control Gradient
±1℃
Sample Position
50 positions
Desorption Recovery Rate
>98%(related to components)
Backflushing Cleaning Flow
0~100ml/min(continuously adjustable)
Analog Sampling Flow
100ml/min
Power Supply
AC220V, 50/60Hz (Standard); 110V, 60Hz(Optional, External transformer)
External Size(W*D*H)
432*508*600mm
Net Weight
39kg
Package Size(W*D*H)
760*610*800mm
Gross Weight
55kg
How ordering works

From enquiry to delivery

  1. 01Send your enquiry

    Request a quote on WhatsApp, or add several items to your enquiry list and send them together.

  2. 02Confirm the details

    We confirm configuration, voltage, accessories, availability and a delivered price.

  3. 03We source and ship

    We handle procurement, packing and international shipping to your facility.

Need a different configuration?

Tell us the application, capacity or budget. We will suggest the right model or source an alternative.

Talk to our team
Request a quote